SUMMARIZE
FKJ-A2 wind turbine auto-controller
is special matched
equipment with wind turbine. It commutates the
AC that generated by wind turbine to DC and then
charges to storage battery groups.
FKJ-A2 auto-controller has a beautiful
appearance, simplify
indication,
and it is easy to operate. It has a
protection of the converse connection of the
batteries. The wind turbine will unload
automatically when the batteries voltage reach
to 125% of the normal voltage; and the wind
turbine will resume working when the batteries
low down to the 108% of the normal voltage. The
user can adjust the potentiometer to change the
unload voltage. The key component adopts the
high-efficient chip control, the complete
machines is intelligent. This system is running
safely, steadily, and reliably, working
efficiently and have a long work life, which is
proved by a large number of experiments.
OPERATION METHOD
I.
Out-linked wire
1.
Connect the “+” & “-”poles of storage battery
separately to the back panel’s “+” & “-” poles
(or terminal blocks) of the charge controller.
Take strict precautions against wrong polarity
connection or short circuit.
2.
Connect 3-phase output wires of wind turbine
separately with the connectors on the
controller’s back panel (No order among A.B.C)
3. Connect the
shunt (unload) of the turbine with a, b, c
terminal blocks in the controller separately.
II Caution: When the poles are wrongly
connected, blowout, reversed indicator will
shine.
1.
When the battery’s voltage is lower than
the discharging bottom limit (see the details in
the attached form), the shortage indicator
shines, it reminds the user that it is in the
discharging lower limit and needs charge.
2.
When the charging fuse breaks, the
charging fuse indicator will shine to remind the
user to change the fuse.
3.
When the wind turbine is working, it is
not allowed to open or change the fuse, so as to
avoid the user from being hurt or damage the
machine. When user change the fuse, the wind
turbine should in brake state, shut off all the
switches, braking the connection of the battery
and then check or change the fuse.
4.
When the batteries voltage reach to the 125% of
rated voltage, the wind turbine will unload
automatically, stop charging to the battery, the
unload indicator light will shine at the same
time, the current meter has no show. when the
batteries voltage low down to the 108% of rated
voltage, the unload indicator light will go out,
the wind turbine will resume working and charge
to the batteries automatically.
III. Manual brake switch
1.
After connected the storage battery
correctly, press the button to “ON” position in
the back panel, the turbine is under the
condition of automatic working. (Small power
controller with this equipment, larger power
charger controller user will self-provided to
install)
2.
Press the wind turbine button to “OFF”
position when without using this machine.
3.
When the controller which rated power is
above 3kw, it is forbidden to operate the manual
breaking switch when the wind turbine is
working.

|
No. |
SPEC |
|
1 |
1000W-48V |
|
2 |
1000W-24V |
|
3 |
2000W-120V |
|
4 |
2000W-48V |
|
5 |
2000W-24V |
|
6 |
3000W-120V |
|
7 |
3000W-48V |
|
8 |
5000W-120V |
|
9 |
5000W-48V |
|
10 |
10KW-240V |
|
11 |
20KW-480V |
|