SUMMARIZE
FKJ-A
wind turbine auto-controller
is special matched
equipment with wind turbine. It commutates the
AC that generated by wind turbine to DC and then
charges to storage battery groups.
FKJ-A auto-controller with a beautiful
appearance,
simplify indication,
easy operation, has an auto-protection
function in case of battery converse connection;
auto-shunt in case of heavy wind (unload). The
wind turbine shut down automatically when the
battery group voltage get to 125%; and startup
automatically when the voltage drop to 108%. The
key component adopts the high-efficient chip
control, the complete machines is intelligent.
This system is running safely, steadily, and
reliably, working efficiently and have a long
work life, which is proved by a large number of
experiments.
OPERATION PROCESS
I.
Out-linked wire
1.
Connect the “+” & “-”poles of storage battery
separately to the back panel’s “+” & “-” poles
(or terminal blocks) of the charge controller.
Take strict precautions against wrong polarity
connection or short circuit.
2.
Connect 3-phase output wires of wind turbine
separately with the connectors on the
controller’s back panel (No order among A.B.C)
3. Connect the
shunt (unload) of the turbine with a, b, c
terminal blocks on the back of the controller
separately.
II Caution: When the poles are wrongly
connected, blowout, reversed indicator will
shine.
1.
When the battery’s voltage is lower than
the discharging bottom limit (see the details in
the attached form), the shortage indicator
shines, it reminds the user that it is in the
discharging lower limit and needs charge.
2.
When the charging fuse breaks, the
charging fuse indicator will shine to remind the
user to change the fuse.
3.
When the wind turbine is working, it is
not allowed to open or change the fuse, so as to
avoid the user from being hurt or damage the
machine. When user change the fuse, the wind
turbine should in brake state, shut off all the
switches, braking the connection of the battery
and then check or change the fuse.
4.
When the wind speed is too high or the
storage battery is close to enough charging, the
shunting boxes works and the shunt indicator
shine. At this moment the wind turbine continue
charge little electric current into battery.
5.
When the battery is sufficiently charged and the
voltage get to125%, the wind turbine
will automatically stop charging and the stop
indicator will shine at the same time. There is
no indication for the Ampere Meter. When the
battery voltage drop to 108% of the rated
voltage, the stop indicator and shunt indicator
will quench and the wind turbine
will resume to work and then charge to the
battery automatically.
III. Manual brake switch
1.
After connected the storage battery
correctly, press the button to “ON” position in
the back panel, the turbine is under the
condition of automatic working. (Small power
controller with this equipment, larger power
charger controller user will self-provided to
install)
2.
Press the wind turbine button to “OFF”
position when without using this machine.
3.
When the controller which rated power is
above 3kw, it is forbidden to operate the manual
breaking switch when the wind turbine is
working.

|
NO. |
SPEC |
|
1 |
300W-12V |
|
2 |
300W-24V |
|
3 |
500W-12V |
|
4 |
500W-24V |
|
5 |
1KW-24V |
|
6 |
1KW-48V |
|
7 |
2KW-48V |
|
8 |
3KW-48V |
|
9 |
3KW-120V |
|
10 |
5KW-120V |
|
11 |
5KW-240V |
|