ZPS Pure full sine
View Detailed
3KW Wind/PV Hybrid
View Detailed
New 100w-300w vert
View Detailed
Off-grid Solar cha
View Detailed
ZKJ-A Charge Contr
View Detailed
PRODUCTS LIST Home > Product Show
ZPS Pure full sine wave inverter

Product Numbers: ZPS 1~12KW

Price: US $

Product description:ZPS Pure full sine wave inverter

INTRODUCTION





Features:
  • Pure sine wave output, available for sensitive load
  • 4-step progressive charging, 7 battery type selector
  • Fast and powerful charger with 30A and 70A
  • Accept generator’s energy output
  • High power factor
  • Automatically transfer between battery and line modes
  • Microprocessor control guarantees high reliability
  • Bypass without battery connected
  • Remote control function
Protection against:
  • Over load, over temperature, over charging, low battery
  • Reverse connection(optional by hard connector)
  • blackouts
Model No.
ZPS-1KW
ZPS-2KW
ZPS-3KW
ZPS-4KW
ZPS-5KW
ZPS-6KW
Nominal Power
1000W
2000W
3000W
4000W
5000W
6000W
AC Input
Phase & waveform
Single phase & sine wave
Voltage
120VAC/230VAC
Acceptable Voltage
194-243VAC\164-243VAC(wide mode)
Line Low Transfer
85V±4%/184(154 wide mode±4%)
Line Low Return
95V±4%/194(164 wide mode±4%)
Line high Transfer
135V±4%/253±4%
Line high Return
127V±4%/243±4%
Frequency
50Hz or 60Hz (auto sensing)
Line Low Transfer
47Hz for 50Hz,57Hz for 60Hz
Line high Transfer
55Hz for 50Hz,65Hz for 60Hz
Output      
Phase & waveform
Single phase & sinewave(bypass mode sync to input)
Voltage
230VAC(bypass mode sync to input)
Voltage Regulation
±10%rms(bypass mode sync to input)
Frequency
50Hz±0.3Hz(bypass mode sync to input)
Crest Power
3 times of ratings
Short Circuit Protection
Yes,shutdown after 10 minutes
Power Factor
0.9-1.0
DC Input      
Battery Voltage
12V/24V
12V/24V/48V
24V/48V
Minimum Start Voltage
10V for 12V,20V for 24V,40V for 48V
Low Battery Alarm
10.5V for 12V,21V for 24V,42V for 48V
Low Battery Transfer
10V for 12V,20V for 24V,40V for 48V
High Voltage Alarm
16V for 12V,32V for 24V,64V for 48V
Max Charging Current
70A\35A
Over Charge Voltage
15.7V for 12V,31.4V for 24V,62.8V for 48V
Transfer Efficiency      
line Mode
>95%
Battery Mode
>88%
power saver
Available when the load is less than 25 Watts
Indicators
7-LED Display
From the right to the left,LED1 line mode (green lighting)、LED2 inverter mode
(green lighting)、LED3 charging mode(yellow lighting)、LED4 Fully charged 
(green lighting)、LED5 over heat shutdown(red lighting)、LED6 Overloaded 
shutdown(red lighting)、LED7 Saving Mode(green lighting)
3-LED Display
Charging Mode(green lighting)、inverter mode(green lighting)、 Alarm(red lighting)
Switch selector
Saving Mode is on/off when push the switch forwards/backwards, keeping it horisontal is 
turning the inverter off.    
Audible Alarm
Sounding when the heatsink's tem is over 105℃ an
Dimension,D X W X H(mm)
218X179X442
 218X179X598 



Inverter Output

Model

ZPS-8.0KW

ZPS-10.0KW

ZPS-12.0KW

Continuous Output power

8.0KW

10.0KW

12.0KW

Surge Rating (20ms)

24.0KW

30.0KW

36.0KW

Output Waveform

Pure Sine wave/Same as input(Bypass Mode)

Nominal Efficiency

>88%(Peak)

Line Mode Efficiency (Line Mode)

>95%

Power Factor

0.9-1.0

Nominal Output Voltage rms

100-110-120Vac/220-230-240Vac

Output Voltage Regulation

±10% RMS

Output Frequency

50Hz±0.3Hz/60Hz±0.3Hz

Short Circuit Protection

Yes(1 sec after fault)

Typical transfer Time

10ms(Max)

THD

<10%

DC Input

Nominal Input Voltage

12.0Vdc

(*2 for 24Vdc,*4 for 48Vdc)

Minimum Start Voltage

10.0Vdc

Low Battery Alarm

10.5Vdc/11.0Vdc

Low Battery Trip

10.0Vdc/10.2Vdc

High Voltage Alarm

16.0Vdc

Low Battery Voltage recover

16.5Vdc

Idle Consumption-Search Mode

<25W when Power Saver On

Charger

Output Voltage

Depends on battery type

Charge Breaker Rating

40A

40A

40A

Max Charge Power Rate(1/3 Rating Power)

1/3 Rating Power

Battery Initial Voltage for Start Up

10-15.7V for 12V(*2 for 24V,*4 for 48V)

Over Charge Protection Shutdown

15.7V for 12V(*2 for 24V,*4 for 48V)

Remote Control

Yes(Optional)

Bypass & Protection

Input Voltage Waveform

Sine wave(Grid or Generator)

Nominal Voltage

220Vac

230Vac

230Vac

Max Input AC Frequency

150VAC For 120Vac LV Mode;300VAC For 230Vac HV Mode

Nominal Input Frequency

50Hz or 60Hz(Auto detect)

Low Freq Trip

47Hz±0.3Hz for 50Hz,57Hz±0.3Hz for 60Hz

High Freq Trip

50Hz±0.3Hz for 50Hz,60Hz±0.3Hz for 60Hz

Overload protection (SMPS load)

Circuit breaker

Output Short circuit protection

Circuit breaker

Bypass breaker rating

50A

63A

63A

Transfer switch rating

40 amp for UL

80 amp for UL

Bypass without batttery connected

Yes(Optional)

Max bypass current

40amp

80amp

Mechanical Specification

Mounting

Wall Mount

Inverter Dimensions (L*W*H)

588*415*200

Inverter Weight (Solar Chg)KG

60+2.5

66+2.5

70+2.5

Shipping Dimensions (L*W*H)

750*520*310

Shipping Weight (Solar Chg)KG

62+2.5

68+2.5

72+2.5

Display

Status LEDs/Status LEDs+LCD

Standard Warranty

1 Year(Optional)





Links:Globalsources  |   SUNMOY  |   EXMORK  |   TERWIN  |  
  Copyright 2017 All Right Reserved EXMORK NEW ENERGY COMPANY  浙ICP备10036942号-1
  Add:No.2,Ningkang West Road,Yueqing, Zhejiang,325600 P.R.China Tel:86-577-62529820 Fax:86-577-62539820